Decision summary: The Cardinal 190 Storm is an IP69K washdown weight indicator with color-changing checkweighing cues; it is a component that must be paired and configured with a compatible scale base/load cells.
Best fit
Food processing, chemical, pharmaceutical, recycling, and harsh washdown environments that need a sealed indicator, large backlit display, checkweighing color cues, and serial connectivity.
Choose the right configuration
Power is not selectable on this page. Confirm AC, DC, or rechargeable-battery configuration and the required load-cell/serial wiring before ordering.
Key specifications
| Specification |
Details |
| Enclosure |
IP69K-rated polycarbonate/ABS; wall or desk mount |
| Washdown test exposure |
Up to 1450 psi and 176 °F / 80 °C |
| Display |
6-digit, 1 in high backlit LCD with ColorZONE |
| Interface |
1 bi-directional RS-232 port |
| Load cells |
Supports up to six 350-ohm load cells |
| Power |
100–240 VAC; 190DC and rechargeable options available |
| Operating environment |
14–104 °F / −10–40 °C; 90% RH non-condensing |
Tradeoffs and relevant alternatives
- If a complete washdown bench scale is needed, compare the Cardinal/Detecto EB-190 bench-scale series.
- For a complete IP69K bench scale with the 190 family indicator, compare the Detecto Admiral CA-190 bench scale.
- Indicator capacity, divisions, and trade suitability depend on the configured scale base, load cells, calibration, and jurisdictional approval—not on the indicator alone.
What is included or required
Cardinal 190 Storm indicator in the ordered power/configuration. A scale base, load cells, junction box, cables, mounting hardware, and calibration service are not assumed included unless specified on the quote.
Certification and trade-use status
Indicator certification only: Cardinal lists NTEP Certificate of Conformance 10-084A1 for the 190 and 190A digital indicators. This does not certify a complete scale assembled with the indicator. Every other component and the final configuration must satisfy the applicable certificate and local placing-in-service requirements.
Warranty
Cardinal’s published 190 Storm product information does not state a warranty duration. Northline can confirm the applicable warranty and selected-option coverage before order.
Shipping & Support
Most orders ship free to the Lower 48 United States. Confirm the selected power option, mounting requirements, lead time, and commissioning/calibration scope before fulfillment.
Frequently asked questions
Is the whole scale NTEP-approved if I use this indicator?
No. The cited certificate covers the 190/190A indicator component. The load receiver, load cells, configuration, calibration, and installation must also comply.
Is the rechargeable battery standard?
The manufacturer lists AC, DC, and rechargeable choices, but this page does not identify one as the selected default. Confirm the power package before ordering.