Decision summary: The SL-927-250K is a specialized 125-ton wireless tension-link package for high-capacity load monitoring, supplied with two shackles and an IP67-rated link body.
Best fit
Engineered lifting and load-monitoring applications where the 250,000 lb capacity, wireless readout, environmental rating, and documented safety margins fit an approved rigging plan.
Choose the right configuration
This is a single 250,000 lb configuration. Its manufacturer-stated measurement accuracy is ±0.1% of full scale; that is approximately ±250 lb and should be assessed against the decision being made.
Key specifications
| Specification |
Details |
| Rated capacity |
250,000 lb / 125 tons |
| Stated accuracy |
±0.1% full scale |
| Enclosure |
IP67 |
| Operating range |
−30 to 70 °C / −22 to 158 °F |
| Safe / ultimate overload |
150% / 200% of rated capacity |
| Construction |
Alloy steel |
Tradeoffs and relevant alternatives
- For lower capacities and both tension/compression fixture use, compare the SellEton SL-926 tension and compression scale system.
- At this capacity, rigging engineering, shackle compatibility, calibration planning, and jurisdictional safety requirements must be resolved before use.
- A ±0.1% full-scale specification is not ±0.1% of the displayed load; evaluate the absolute uncertainty at the loads you expect to measure.
What is included or required
SL-927-250K wireless tension link, two shackles, wireless readout components, and manufacturer documentation for the supplied package.
Warranty
SellEton lists a 5-year warranty for this model. Coverage is subject to the manufacturer’s written terms, exclusions, and operating conditions.
Shipping & Support
Most orders ship free to the Lower 48 United States. Residential, farm, rural, liftgate, and expedited charges may apply. Typical manufacturer processing is 5–7 business days; Northline will confirm current availability and freight details at order.
Frequently asked questions
Does the capacity rate the entire lifting system?
No. Every shackle, sling, crane, attachment point, and procedure needs its own compatible rating and approval.
What does ±0.1% full scale mean?
On a 250,000 lb range, the stated full-scale accuracy corresponds to about 250 lb, independent of the current displayed load.